Our Products

Rotary Evaporator

Laboratory equipment

Jacketed Reactor

Contact Us

We Cherish All Interactions

SOP: Cleaning a Laboratory Balance - METTLER TOLEDO

SOP: Cleaning a Laboratory Balance - METTLER TOLEDO

Scope. This SOP describes the procedure for cleaning a laboratory (bench top) balance (both analytical balance and precision balance). It is designed to instruct laboratory personnel on how to proceed for thorough cleaning of a balance.

General Purpose Water Baths General Purpose Water Baths

General Purpose Water Baths General Purpose Water Baths

PolyScience Water Baths, available in a range of capacities from 2 liters to 28 liters in both economy and digital models, provide the perfect blend of scientific accuracy and utility for day-to-day laboratory tasks. 86-87 Digital 88-89 Economy 90-91 General Purpose Water Bath Accessories General Purpose Water Baths

Water Baths | JULABO

Water Baths | JULABO

PURA water baths stand for a straightforward and safe working in the laboratory. The high-quality water baths offer a temperature stability of ± 0.15 °C 2). The working temperature range of +18 °C to 99.9 °C 1) allows a wide range of applications, such as routine laboratory work, temperature applications for samples, incubation, material .

Standard Operating Procedures (SOP) for Cell Culture .

Standard Operating Procedures (SOP) for Cell Culture .

Once a week, water baths must be completely emptied and cleaned. The water used for replacement . Standard Operating Procedures (SOP) for cell culture rooms when Biosafety Level Two (BSL2) . of this laboratory shall be placed in a durable, leak proof container which will be closed for transport.

Cleaning Glassware | Protocol

Cleaning Glassware | Protocol

With warm tap water, use an appropriate brush and soapy water to scrub the inside of curved glassware. Remove soapsuds using warm tap water. To avoid hard water stains, use deionized water or reverse osmosis water to wash away tap water. Rinse again with acetone to remove water. This step helps to expedite the glass drying process. 2. General .

CLSI Guideline for Clinical Laboratory Reagent Water .

CLSI Guideline for Clinical Laboratory Reagent Water .

May 18, 2016 · Clinical Laboratory Reagent Water can now be used in place of Type I and II water for most applications. Autoclave and wash water will generally be a satisfactory replacement for Type III water. 2. Total Organic Carbon (TOC) parameter has been added. Perhaps the most significant change of this guideline is the addition of the TOC parameter.

SOP on Media Preparation - Pharmaceutical Guidance

SOP on Media Preparation - Pharmaceutical Guidance

SOP on Media PreparationObjective: To lay down the procedure for Preparation of Media. Scope: This SOP is applicable for preparation of sterile media used in Microbiology Laboratory of (Pharmaceutical Company Name). Responsibility: Microbiologist or above of Microbiology Laboratory. Head – Microbiology section. Accountability: Head – Quality Control Head – Quality Assurance.

Installation and Operation Manual

Installation and Operation Manual

3.05 The interior of the bath is constructed of stainless steel and is designed for operation with distilled water or water solutions, such as water ethylene glycol with corrosion inhibitor's added. The body is made from galvanized steel and is painted for added protection. A gable cover is also provided with the bath.

Guidelines for Food Testing Laboratories

Guidelines for Food Testing Laboratories

4.14.1 The laboratory shall conduct an internal audit on an annual basis. All audit records shall be kept in the laboratory. 4.15 . Management reviews. 4.15.1 The laboratory shall conduct annual management reviews. The management review shall be conducted such that it can address the outcome of the recent internal audit. 5 . Technical .

Laboratory Procedure Manual

Laboratory Procedure Manual

Microalbumin in Urine – NHANES 2001-2002 1. SUMMARY OF TEST PRINCIPLE AND CLINICAL RELEVANCE A fluorescent immunoassay for the measurement of human urinary albumin is described by Chavers et al.1 The methodology involves solid-phase, non-competitive, double-antibody reaction.

Laboratory water bath - Wikipedia

Laboratory water bath - Wikipedia

A water bath is laboratory equipment made from a container filled with heated water. It is used to incubate samples in water at a constant temperature over a long period of time. Most water baths have a digital or an analogue interface to allow users to set a desired temperature, but some water baths have their temperature controlled by a current passing through a reader.

Operation, Calibration, Cleaning and Maintenance of .

Operation, Calibration, Cleaning and Maintenance of .

This SOP is applicable for Operation, Calibration, Cleaning and Maintenance of bacteriological Incubator in Microbiology lab (Pharmaceutical Company Name). Responsibility Microbiologist or above of Microbiology Laboratory: Preparation of SOP.

SOP: Cleaning a Laboratory Balance - METTLER TOLEDO

SOP: Cleaning a Laboratory Balance - METTLER TOLEDO

Scope. This SOP describes the procedure for cleaning a laboratory (bench top) balance (both analytical balance and precision balance). It is designed to instruct laboratory personnel on how to proceed for thorough cleaning of a balance.

Precision Water Baths | Thermo Fisher Scientific - IN

Precision Water Baths | Thermo Fisher Scientific - IN

Thermo Scientific Precision water baths are:. Compact—Save valuable bench space with the small footprint of our general purpose baths.; Effortless—Automatically preheat and turn off your bath for efficient work scheduling with new auto-on and auto-off timers. Intuitive—Simplify parameter setting and monitoring with new icon-based controller interface to help ensure safe operation.

STANDARD OPERATING PROCEDURE FOR VARIOUS .

STANDARD OPERATING PROCEDURE FOR VARIOUS .

to standard operating procedure (SOP) and using personal protective equipment (PPE) where applicable. The use of UV in the laboratory is governed by „The control of Artificial Optical Radiation at Work Regulations 2010‟ UV light emitted from a transilluminator .

Blog Teknik Laboratorium: SOP menggunakan Water Bath

Blog Teknik Laboratorium: SOP menggunakan Water Bath

SOP menggunakan Water Bath Waterbath - Penangas Air. Pengertian : . Water bath menggunakan daya listrik yang rendah sehingga sangat ekonomis dan efisien. Secara sederhana alat ini menggunakan pemanas pada air yang dipanaskan dengan api maupun dengan listrik atau uap dari air.

Standard Operating Procedure: Glassware Cleaning

Standard Operating Procedure: Glassware Cleaning

Standard Operating Procedure: Glassware Cleaning Using clean glassware is key to the success of a chemical reaction, and cleaning glassware is part of good lab citizenship. All members of the lab must contribute to this. . are present when putting frits in the acid or DI water baths.

STANDARD OPERATING PROCEDURE FOR .

STANDARD OPERATING PROCEDURE FOR .

This Standard Operating Protocol (SOP) manual is a guideline intended to assist as a reference material for routine laboratory activities in mycobacteriology lab. This guideline clearly spells out what is expected and required of personnel while handling mycobacteria during their day-to-day activities in the laboratory. SOPs provide a

How to Clean a Waterbath (When You Can't Avoid it Any .

How to Clean a Waterbath (When You Can't Avoid it Any .

Apr 20, 2012 · There's something disconcerting about going to incubate a sensitive and irreplaceable sample in a water bath, only to be confronted by the Creature from the Black Lagoon. Unfortunately, water baths are an inviting habitat for all kinds of life, are often shared by many users, and are a perennially unpopular item to clean. To help you overcome your fears of the monsters lurking in the water .

SOP for Water Bath : Pharmaceutical Guidelines

SOP for Water Bath : Pharmaceutical Guidelines

5.3.4 After completing the calibration make entry in the calibration record of water bath. 6.0 ABBREVIATIONS 6.1 SOP - Standard Operating Procedure 6.2 ºC - Degree centigrade 6.3 DTC - Digital temperature controller

SOP Waterbath - Download Documents

SOP Waterbath - Download Documents

Dec 14, 2015 · SOP Waterbath There is document - SOP Waterbath available here for reading and downloading. Use the download button below or simple online reader. The file extension - PDF and ranks to the Documents category.

Water Baths: Heated, Digital & Shaker Baths - Cole-Parmer

Water Baths: Heated, Digital & Shaker Baths - Cole-Parmer

Water baths are ideal for maintaining temperature set points over a long period of time. Different sizes and depths of the bath chamber are available to meet your application. Utility baths are available in analog or digital temperature control with ranges from ambient to 100 degrees C. Options with high-temperature and low-level cutoff .

Standard Operating Procedure for Base Bath Cleaning .

Standard Operating Procedure for Base Bath Cleaning .

To make a new base bath, potassium hydroxide (500g) should be first dissolved in 1L water in a beaker. Beware that the solution will become very hot upon dissolution. This solution should be added to 12L of isopropanol in a large Nalgene container. 4. Base Bath Waste Disposal Base bath should be disposed of like any other caustic solution.

SOP for Safety In Quality Control Laboratory .

SOP for Safety In Quality Control Laboratory .

May 11, 2019 · SOP for Safety In Quality Control Laboratory . Removal of solvents in an experiment involving flammable solvents should be carried out using a water-bath or electrically heated bath. For low-boiling liquids such as liquor ammonia, ether, etc., cool the container before opening, using protective equipment such as gloves and safety goggles. .

Title: Base Bath Page 1 of 4 Base Bath

Title: Base Bath Page 1 of 4 Base Bath

Base bath in the Beckman lab is located by the sink at the southeast corner (neareast the door) in room 3724 BI. This SOP includes potential hazards of the base bath, proper equipment required, operation procedure and cautions for the use of the base bath. It aims to guiding the lab users to use the base bath

Standard Operating Procedure

Standard Operating Procedure

Standards Laboratory SOP 005 . First edition . MONITORING AND LABORATORY DIVISION . MARCH 2014 . TABLE OF CONTENTS . . Note: The Humilab's chamber environment sits inside a water bath. It is . Standard Operating Procedure .

Procedure for operation of water bath - Ichapps

Procedure for operation of water bath - Ichapps

1.1 to lay down the procedure for operation of water bath, (neolab). equipment identification no: xxxxx. 2.0 scope. 2.1 this sop covers the operation procedure of water bath. 3.0 responsibility . 3.1 microbiologist. 3.0 accountability . 4.1 head - quality control. 5.0 procedure

Standard Operating Procedure for Base Bath Cleaning .

Standard Operating Procedure for Base Bath Cleaning .

To make a new base bath, potassium hydroxide (500g) should be first dissolved in 1L water in a beaker. Beware that the solution will become very hot upon dissolution. This solution should be added to 12L of isopropanol in a large Nalgene container. 4. Base Bath Waste Disposal Base bath should be disposed of like any other caustic solution.

SOP for Cleaning of Water Bath : Pharmaceutical Guidelines

SOP for Cleaning of Water Bath : Pharmaceutical Guidelines

5.5 Fill purified water up to 3/4 th height of the bath. 5.6 Put the lid of the bath. 5.7 After completion of cleaning of the water bath, record in the format. Note: In between when water becomes dirty follow the same from 5.1 to 5.7 6.0 ABBREVIATIONS 6.1 SOP - Standard Operating Procedure

Fact Sheet: Acid and Base Baths for Glassware Cleaning .

Fact Sheet: Acid and Base Baths for Glassware Cleaning .

Standard lab attire, lab coat, full-length pants or equivalent, and fully enclosed shoes. Chemical-resistant apron may be worn over the lab coat to protect against splashes. Eye & Face Protection. If there is a splash potential, tight-fitting splash goggles are recommended along with a face shield or protection from a hood sash. Hand Protection