Our Products

Rotary Evaporator

Laboratory equipment

Jacketed Reactor

Contact Us

We Cherish All Interactions

Heating Bath Circulators, 250°C High Temperature

Heating Bath Circulators, 250°C High Temperature

The CH series of commonly used high temperature circulating baths are designed for external temperature control such as used with jacketed reactors. The bath opening also allows for experiments to be carried out in the bath as well. Four models cover the range for standard applications offering temperature control from Ambient +5 to +250ºC and bath capacities of 8, 12, 22 and 30 liters.

Guide to Circulator Pump Relays & Other Controls for .

Guide to Circulator Pump Relays & Other Controls for .

Heating system circulator pump troubleshooting: here we list & describe other heating system controls that manage or impact heating boiler circulator pump operation. This article series discusses Circulator Pumps: how to find, inspect, diagnose, and repair problems with Hot Water Heating System Circulator Pumps or circulator pump relay switches and controls.

Q106189 - Bell & Gossett Q106189 - 1/12 HP, Series 100 NFI .

Q106189 - Bell & Gossett Q106189 - 1/12 HP, Series 100 NFI .

Bell & Gossett Q106189 - 1/12 HP, Series 100 NFI Circulator Pump w/ EPT High Temp Seal - THREE-PIECE, OIL LUBRICATED BOOSTER PUMP. The industry standard circulator for decades, Series 100 is still the one by which most others are judged. With well over 10 million units installed, the Series 100 remains a leader in applications such as hydronic heating and domestic hot water circulation.

Consulting - Specifying Engineer | Balancing a domestic .

Consulting - Specifying Engineer | Balancing a domestic .

Some mixing stations just have a common control valve. Other more complicated stations may have a TMV, circulation pump, aquastats for pump control, high-temperature safety limits (anti-scald valves), multiple pressure-reducing valves, control valves, isolation valves, and monitoring sensors.

Pump - Volume Flow and Temperature Rise

Pump - Volume Flow and Temperature Rise

A typical relation between flow, efficiency and power consumption for a centrifugal pump: Pump - Temperature Rise Calculator. P s brake power (kW) Example - Temperature rise in water pump. Temperature rise in a water pump working at normal conditions with flow 6 m 3 /h (0.0017 m 3 /s), brake power 0.11 kW and pump efficiency of 28% (0.28) can .

MTH Pumps - Find your Application

MTH Pumps - Find your Application

One is a circulation pump which continuously filters the water supply and supplies the feed pump. The feed pump operates at 120 psi and injects de-ionized water into the process to produce the hydrogen necessary for the chemical to electrical energy conversion.

Hydrocarbon Processing Pumps - Flowserve

Hydrocarbon Processing Pumps - Flowserve

Hydraulic decoking employs high velocity water jets, produced by the decoking tool from water at pressures up to 415 bar (6000 psi). A special purpose double casing pump, rated up to 3500 kW (4700 hp), supplies the high-pressure water. Safe and effective decoking is assured by a custom control system. Since hydraulic decoking was developed in 1938,

Hot Oil Systems | Shini USA - Shini USA | Shini USA

Hot Oil Systems | Shini USA - Shini USA | Shini USA

The Shini USA industrial temperature control hot oil systems are fluid circulating units that control the application temperatures. We offer both low-temperature (350°F) hot oil units and high-temperature (450°F) systems. . The units also come equipped with a centrifugal-type pump, discharge pressure gauge and closed loop cooling.

High Quality Glycol Vortex Circulation Pump In China - Buy .

High Quality Glycol Vortex Circulation Pump In China - Buy .

High Quality Glycol Vortex Circulation Pump In China, Find Complete Details about High Quality Glycol Vortex Circulation Pump In China,High Temperature Oil Pump,Temperature Control Circulation Pump,Vortex Temp from Pumps Supplier or Manufacturer-Kunshan Aulank Pumps Manufacturing Co., Ltd.

Hot Oil Pump | High Temperature Pump | Magnet Drive Hot .

Hot Oil Pump | High Temperature Pump | Magnet Drive Hot .

Temperature: -40°F to 535°F MPH Series - Mag Drive Pumps designed for low flow, medium to high head, high-temperature applications. MPH Series pumps .

Pump - Volume Flow and Temperature Rise

Pump - Volume Flow and Temperature Rise

A typical relation between flow, efficiency and power consumption for a centrifugal pump: Pump - Temperature Rise Calculator. P s brake power (kW) Example - Temperature rise in water pump. Temperature rise in a water pump working at normal conditions with flow 6 m 3 /h (0.0017 m 3 /s), brake power 0.11 kW and pump efficiency of 28% (0.28) can .

Circulator Pumps

Circulator Pumps

A pump (circulator) is the heart of a hydronic system. Pumps move water through the system at a desired rate. They may be utilized in a primary loop or for zoning purposes. Pumps require a flange to connect to a supply line. There are many important factors to consider when purchasing a pump such as application, GPM, head range, material .

(PDF) A techincal report on design of hot oil system

(PDF) A techincal report on design of hot oil system

pressure to carry out high temperature operation owing to . filter in 1 working + 1 stand by arrangement at a side stream bypass line around circulation pump . . control through cooler when .

Aquastat Temperature Control | Boiler Components

Aquastat Temperature Control | Boiler Components

This setpoint change will be based on the outside ambient air temperature. The cutout temperature is when the boiler reaches the high setpoint and turns off the burners. The circulator pump may still be running with the burners off. The cutout temperature should never exceed 200° F.

How to Hook Up a Thermostat to a Circulating Pump .

How to Hook Up a Thermostat to a Circulating Pump .

If you have installed a circulating pump in your hot water system, you may have also decided that the efficient method to keep it running properly is to also install a thermostat and control. Like any thermostat, the circulating pump thermostat is used to regulate the temperature of the hot water and turn on and off the pump as necessary to ensure that hot water is appropriately flowing .

High Temperature Pump | High Temp Pump | High Temp .

High Temperature Pump | High Temp Pump | High Temp .

HIGH TEMPERATURE PUMP-MPH SERIES. Excellent for High Temperature service. Max Flow: 150 GPM; Max Head: 190 Feet; Temperature: -40°F to 535°F

: Grundfos 595443 Thermostatic Control (85-105F .

: Grundfos 595443 Thermostatic Control (85-105F .

After a period of time, when the pipe warms to the operating temperature, the switch opens and shuts off the pump. Run time depends on the temperature of the hot water in the tank and the size of your plumbing system, however in my home the switch generally shuts the pump off in about 4 minutes or so. It comes back on in about 20.

How the boiler circulating pump works. - YouTube

How the boiler circulating pump works. - YouTube

Nov 10, 2012 · A description of the water lubricated circ pump used on most residential and light commercial hot water boiler systems. This video is part of the .

Grundfos' intelligent controls for instant hot water .

Grundfos' intelligent controls for instant hot water .

The constant temperature control mode on the TPE3 will always maintain the desired water temperature at the taps and in the circulation pipe. If the temperature increases the pump ramps down and if temperature decreases the pump will increase its performance.

Recirculation pump | Grundfos

Recirculation pump | Grundfos

A recirculation pump can be sized for a given system using the following formulas: Water flow qc= Φ/ΔT x 4200 qc = the circulating water flow [m 3 /s] Φ = heat loss from the circulation system [kW] ΔT = the water cooling, normally 5°C determined at the farthest consumption point [°C]

Hot Water Circulator on-Demand Circulation Recirculation Pump

Hot Water Circulator on-Demand Circulation Recirculation Pump

With energy-saving features including "temperature based" cyclic pumping, adjustable temperature control, and scheduled-off "single-cycle" override, it's easy to see why ReadyTemp® is the industry's "homeowner preferred" hot water circulation pump.

Hot Water Recirculation Pumps | Grundfos

Hot Water Recirculation Pumps | Grundfos

The ALPHA 15-55 HWR-D is a recirculation system that delivers hot water in homes at the push of a button and can save thousands of gallons of water each year. The system includes an ALPHA 15-55 circulator pump (with a permanent magnet motor), a temperature sensor and two push button controls. Literature - General Brochure

Heating Circulators | JULABO USA, Inc.

Heating Circulators | JULABO USA, Inc.

The adjustable bridge permits use of the circulator with a wide variety of bath tanks. This model is suitable for both internal and external temperature control tasks. It has the power to control the temperature of even large bath tanks up to 100 L. An integrated cooling coil enables temperature control below or near the ambient temperature.

Circulation Heaters | Electric Process Circulation Heater

Circulation Heaters | Electric Process Circulation Heater

An electric process circulation heater is used as a conduit to facilitate the flow of process fluid directly over heating elements. Circulation heaters heat a variety of fluids from high-temperature gas to hard to heat liquids. The heating elements, vessel, terminal connections, and mounting structures are packaged for quick installation.

Recirculating Pumps - Utility Pumps - The Home Depot

Recirculating Pumps - Utility Pumps - The Home Depot

GOULDS WATER TECHNOLOGY Laing Thermotech E Series E1-BCUNRN1W-06 Non-Timer Ultracirc 0.02 HP Circulating Pump w/ Adjustable Thermostat and Plug Model# 6050U5013 (3)

How to Fix Your Spa | Dimension One Spa Troubleshooting

How to Fix Your Spa | Dimension One Spa Troubleshooting

Step 2 – Immediately Purge an Air Lock in Your Circulation Pump; Step 3 – Cleaning Your Filters & Mesh Screen; Step 4 – Clearing the Flow Lines with a Small Compressor; Step 5 – Remove and Clean the Circulation Pump; Step 6 – Flushing the Temperature Sensor Assembly

Heating System Boiler Limit Controls & Strap-On Aquastats

Heating System Boiler Limit Controls & Strap-On Aquastats

One limit control is the high temperature shut-off for the burner, the other controls the circulation pump. The boiler is currently set to 180, which seems right to me. My question is, what temperature should the circulation pump temperature sensor be set for? Reply: Jim, typically the high limit control is set 180 to 200. I like 200 as more .

Lochinvar :: FAQs

Lochinvar :: FAQs

What is the minimum return water temperature in a boiler/water heater application? 50 Degrees F. However, currently, there are minimum set point requirements of 70 Degrees F for IB2000, 90 Degrees F for IB1700 and 105 Degrees F for IB1500.

Circulator Pumps - Xylem Applied Water Systems - United States

Circulator Pumps - Xylem Applied Water Systems - United States

Energy Efficient circulators (small in-line pumps) for hydronic heating, potable water recirculation (plumbing), and solar thermal applications. Circulators are cast iron or lead-free bronze constructed with oil lubricated, wet rotor or dry rotor bearings.

Circulator Pumps

Circulator Pumps

A pump (circulator) is the heart of a hydronic system. Pumps move water through the system at a desired rate. They may be utilized in a primary loop or for zoning purposes. Pumps require a flange to connect to a supply line. There are many important factors to consider when purchasing a pump such as application, GPM, head range, material .