Our Products

Rotary Evaporator

Laboratory equipment

Jacketed Reactor

Contact Us

We Cherish All Interactions

Buchi Glass Rotary Evaporator Parts - Evaporators | Sigma .

Buchi Glass Rotary Evaporator Parts - Evaporators | Sigma .

Buchi Glass Rotary Evaporator Parts Assemblies are available in four styles: diagonal, vertical, cold-trap, and cold-trap reflux. They are supplied with either a 24/40 or 29/32 joint on the evaporator flask and a 35/20 ball joint on the receiving flask.

Temperature control,rotary evaporator,glass reactor .

Temperature control,rotary evaporator,glass reactor .

Lab-scale Rotary Evaporator Pilot-scale Rotary Evaporator Rotary Evaporation and Strring solution Dynamic Temperature Control System(ZT Series) Recirculating Chiller(DL Series/LT Series) Cold Trap(CT Series) Low Temperature Circulating Pump(DLSB Series) Water Cooler/Low Temperature Stiming Reaction Bath(DHJF Series) Constant Temperature .

How to hook up cold traps.

How to hook up cold traps.

Aug 23, 2018 · How To Install Short Path Distillation Apparatus, Connect the Circulating Pump and the vacuum pump - Duration: 14:12. Lanphan Henan 9,671 views

Heidolph Instruments : Rotary Evaporators

Heidolph Instruments : Rotary Evaporators

All Hei-VAP rotary evaporators have a safety heating bath with overheating and dry running protection, ergonomic handles, double wall and an integrated spout . Universal heating bath for all flask sizes up to 5 l (no retooling required). The sturdy metal connection to the device's base allows variable distances for the heating bath up to 200 .

Rotary Evaporator Ethanol Extraction - Coldfinger .

Rotary Evaporator Ethanol Extraction - Coldfinger .

Oct 11, 2019 · Rotary evaporators allow many configurations depending on the use. A diagonal glass condenser is common for standard distillation of non-volatile substances. Vertical class condensers allow solvents with higher boiling points. For ethanol extraction with dry ice, a rotary evaporator with a cold finger glass condenser is ideal.

Buchi® cold-trap condenser, for Rotavapor® evaporators .

Buchi® cold-trap condenser, for Rotavapor® evaporators .

Buchi® cold-trap condenser, for Rotavapor® evaporators Inner part, For 210/215; find null-Z319651 MSDS, related peer-reviewed papers, technical documents, similar products & more at Sigma-Aldrich.

Rotary evaporator - Wikipedia

Rotary evaporator - Wikipedia

Rotary evaporation is a technique commonly used in organic chemistry to remove a volatile solvent from a non-volatile compound of interest. Invented by Lyman C. Craig in 1950 the rotary evaporator, or rotovap, gently removes solvents from compounds using heat combined with reduced pressure to evaporate, dry, and purify samples for further downstream use.

Cold Trap

Cold Trap

Rotary evaporator cold trap is an innovative product which used for steam condensation collection of organic solvents. It can be working combined with Sample pretreatment equipment such as Laboratory Parallel Evaporator/Concentration Meter. Read More. Vacuum Condensate Cold Trap.

Buchi - Fisher Scientific

Buchi - Fisher Scientific

Buy Buchi products at Fisher Scientific - Buchi are a supplier of laboratory apparatus and instruments for Science, NIR-Spectroscopy.

: cold trap

: cold trap

Across International SE05c.110 SolventVap 0.5 gal/2 L Rotary Evaporator with Cold Trap Condenser and Manual Lift, 110V, 1525W, 14 Amp 2,334.75 2,334 . 75 FREE Shipping by Amazon

How do I evaporate water and ethanol using a rotary .

How do I evaporate water and ethanol using a rotary .

Does anyone have any suggestions about how I could optimise the rotary evaporator? Currently, I have the water bath temperature at 65'C and the pressure at around -20hg. . If a cold trap, cooled .

Buchi - Fisher Scientific

Buchi - Fisher Scientific

Buy Buchi products at Fisher Scientific - Buchi are a supplier of laboratory apparatus and instruments for Science, NIR-Spectroscopy.

Antibodies & Protein Biology - Fisher Scientific

Antibodies & Protein Biology - Fisher Scientific

Diaphragm pump, cold trap and vacuum gauge (2); Diaphragm pump, cold trap and vacuum gauge, RH40-11 rotor (40 x 1.5-2 mL tube) (1) Diaphragm pump, cold trap and vacuum gauge, RH40-11 rotor (40x1.5-2ml tube) (1) Polypropylene and Stainless Steel spring pressure indicator, Polypropylene flow restrictor and size 16 PVC peristaltic tubing and Nylon fittings (1)

Rotary Evaporator Instructions | Summit Research

Rotary Evaporator Instructions | Summit Research

Summit Research Rotary Evaporator Instructions. Please see diagram as this will show you basic link up procedures for the rotary evaporator . We have been educating & training our customers for years on how to properly integrate rotary evaporators with this process. We do not focus on low power packages that offer little to no recovery speeds.

What is the best method of removing solvents like .

What is the best method of removing solvents like .

Or add a cold trap between the rotarvap and the pump. Cite. 21st May, 2014. . However, I am finding the rotary evaporator very slow at doing this; ~4 hours to evaporate 500ml of the solution .

Rotary Evaporators | Fisher Scientific

Rotary Evaporators | Fisher Scientific

Rotary Evaporators Heidolph™ Hei-Vap™ Rotary Evaporators - Hei‐VAP Value/Hei‐VAP Value Digital Affordable model with hand lift for all standard applications

Rotary Evaporator Instructions | Summit Research

Rotary Evaporator Instructions | Summit Research

Summit Research Rotary Evaporator Instructions. Please see diagram as this will show you basic link up procedures for the rotary evaporator . We have been educating & training our customers for years on how to properly integrate rotary evaporators with this process. We do not focus on low power packages that offer little to no recovery speeds.

Rotary Evaporation - Chemistry LibreTexts

Rotary Evaporation - Chemistry LibreTexts

Most rotary evaporators have four major components: heat bath, rotor, condenser, and solvent trap. Additionally an aspirator or vacuum pump needs to be attached, as well as a bump trap and round bottom flask containing the sample to be concentrated.

What is the purpose of using the rotary evaporator? - Lab .

What is the purpose of using the rotary evaporator? - Lab .

After filling the cold traps, you then have to attach a glass bump trap to prevent the solution from entering into the main part of the rotary evaporator. This is made firm by securing it with a Keck clip. After attaching a Keck clip, attach the pump trap and the flask to the adaptor of your rotary evaporator.

BVV 20L Solvent Pro Series Rotary Evaporator Turnkey .

BVV 20L Solvent Pro Series Rotary Evaporator Turnkey .

BVV 20L Solvent Pro Series Rotary Evaporator Turnkey Setup. 20L Solvent Pro Series Rotary Evaporator turnkey setup includes all the necessary components to successfully perform solvent recovery via rotary evaporation. A cold trap should always be used inline between your vacuum system and application to protect the pump from volatile vapors.

BVV 20L Solvent Pro Series Rotary Evaporator Turnkey .

BVV 20L Solvent Pro Series Rotary Evaporator Turnkey .

BVV 20L Solvent Pro Series Rotary Evaporator Turnkey Setup. 20L Solvent Pro Series Rotary Evaporator turnkey setup includes all the necessary components to successfully perform solvent recovery via rotary evaporation. A cold trap should always be used inline between your vacuum system and application to protect the pump from volatile vapors.

Cold Traps - Across International

Cold Traps - Across International

Openable Glass Trap for Ai T Series -40°C & -80°C Cold Traps Compatible with Ai 1st generation T40 and T80 cold traps, NOT compatible with Gen 2 and Gen 3 that we are currently selling Upward ports allow safer and easier vacuum tubing connection and removel . 1.6X capacity than its predecessor.

IKA RV 10 Digital Rotary Evaporator With Cold-trap Coated .

IKA RV 10 Digital Rotary Evaporator With Cold-trap Coated .

Description IKA RV 10 Digital Rotary Evaporator With Cold-trap Coated Glassware, 115 VAC Includes Universal water/oil heating bath, vertical condenser set, 1-L receiving flask with clamp, 1-L evaporator.

Antibodies & Protein Biology - Fisher Scientific

Antibodies & Protein Biology - Fisher Scientific

Diaphragm pump, cold trap and vacuum gauge (2); Diaphragm pump, cold trap and vacuum gauge, RH40-11 rotor (40 x 1.5-2 mL tube) (1) Diaphragm pump, cold trap and vacuum gauge, RH40-11 rotor (40x1.5-2ml tube) (1) Polypropylene and Stainless Steel spring pressure indicator, Polypropylene flow restrictor and size 16 PVC peristaltic tubing and Nylon fittings (1)

Mini Rotary Evaporator With Cold Trap For Vacuum .

Mini Rotary Evaporator With Cold Trap For Vacuum .

Mini Rotary Evaporator With Cold Trap For Vacuum Distillation, Find Complete Details about Mini Rotary Evaporator With Cold Trap For Vacuum Distillation,Rotary Evaporator,Rotary Vacuum Evaporator,Mini Rotary Evaporator from Evaporator Supplier or Manufacturer-Shanghai HJLab Instruments Co., Ltd.

Cold Trap|Evaporator related products|Product line-up .

Cold Trap|Evaporator related products|Product line-up .

Plenty EYELA product line-up from pre-analysis to production(50 different evaporators).Cold Trap/Product line-up. Rotary evaporator | EYELA as a pioneer of Evaporators

: rotary evaporator

: rotary evaporator

Across International SE13c.220 SolventVap 1.3 gal/5 L Rotary Evaporator with Cold Trap Condenser and Motorized Lift, 220V, 2200W, 10 Amp 4,336.16 4,336 . 16 FREE Shipping by Amazon

The role that cold trap plays in rotary evaporator equipment

The role that cold trap plays in rotary evaporator equipment

rotary evaporator The role that cold trap plays in rotary evaporator equipment. In laboratory, cold trap is a trap that traps gas on a cooled surface in a coagulated manner. It is a device placed between a vacuum vessel and a pump for adsorbing gas or trapping oil vapor.In rotary evaporator equipment, cold trap plays a very important role.

Rotary Evaporator Ethanol Extraction - Coldfinger .

Rotary Evaporator Ethanol Extraction - Coldfinger .

Oct 11, 2019 · Rotary evaporators allow many configurations depending on the use. A diagonal glass condenser is common for standard distillation of non-volatile substances. Vertical class condensers allow solvents with higher boiling points. For ethanol extraction with dry ice, a rotary evaporator with a cold finger glass condenser is ideal.

CG-1320 - ROTARY EVAPORATOR BUMP TRAPS- Chemglass Life .

CG-1320 - ROTARY EVAPORATOR BUMP TRAPS- Chemglass Life .

Used between the vapor tube and evaporation flask on a rotary evaporator to prevent contents of the flask from being drawn into the condenser in the event of "bumping." Traps have a 24/40 top outer joint and the listed size of lower inner joint. Bump Traps are available Plastic Coated. Contact us .