Our Products

Rotary Evaporator

Laboratory equipment

Jacketed Reactor

Contact Us

We Cherish All Interactions

Air Driven Pump | High Pressure Company

Air Driven Pump | High Pressure Company

High Performance Air-Driven Pumps. Supercritical CO2 Extraction Pump System. eTensifier Electric Pump System. PT2020 Automated Pump Controller System. Sprague Air Driven Pumps. Sprague Gas Boosters. Sprague Power Units. Hydraulic Intensifiers: 150,000 psi. Manual Pressure Pump Generators. Standard Shop Pumping Systems. Portable Hydraulic Power .

1L Small Jacketed Glass Chemical Reactor,Glass Reaction .

1L Small Jacketed Glass Chemical Reactor,Glass Reaction .

When necessary, air-driven motors are available upon request t. The 500mL to 5L reactor systems come with a table-top design with maximized accessibility to all components (vessel, lid, condenser, funnel, etc). Any exchange and replacement of components can be done easily.

Nuclear thermal rocket - Wikipedia

Nuclear thermal rocket - Wikipedia

A nuclear thermal rocket (NTR) is a type of thermal rocket where the heat from a nuclear reaction, often nuclear fission, replaces the chemical energy of the propellants in a chemical rocket.In an NTR, a working fluid, usually liquid hydrogen, is heated to a high temperature in a nuclear reactor and then expands through a rocket nozzle to create thrust.

Reactor-Ready Lab Reactor - Radleys

Reactor-Ready Lab Reactor - Radleys

Reactor-Ready accepts all leading brands of motor or air-powered overhead stirrer with support rods up to 16 mm in diameter Whip-free stirrer guide The Reactor-Ready's PTFE stirrer guide screws directly on to the glass lid and features a unique extended support which provides whip-free agitation even at .

Application Note - RAE

Application Note - RAE

Thegeneralruleofthumbisthatanoutputreactorshouldbeusedifthemotorwiringisover00feet,butthisvalue variesdependingonthemotor. IfthemotormeetstheNEMAMG-Part3standard,itispossibletohaveasmuch as300ftofcablingwithoutareactor. Ifitdoesnotmeetthestandard,themaximumcablelengthshouldbe00 ft.

Pump Ratio and Performance Charts

Pump Ratio and Performance Charts

Pressure vs. Volume - Same Air Motor When using the same air motor with different pumps the ratio will change. If the ratio goes up the flow will decrease. If the ratio goes down the flow will increase. Figure 3 illustrates this relationship. Figure 3 Same air motor with different pumps. For example, a pump and motor with a 5:1 ratio at maximum .

Industrial reactor - hydrogenator reactor

Industrial reactor - hydrogenator reactor

Amar-make high pressure reactor, Hydrogenator reactor, industrial reactor and jacketed reactor over 100 ltr volume are completely custom-designed to suit client requirements. These can come equipped with a PLC panel and solenoid/pneumatic actuated values for automated control.

Advancing Power Quality Written by: Josh Haase Line and .

Advancing Power Quality Written by: Josh Haase Line and .

A reactor can also be placed on the load side of a VFD to help protect motors by acting as a useful buffer in between the drive and motor. A standard Pulse Width Modulated (PWM) drive produces a square wave power supply to the electric motor. That modulated square waveform has sharp edges on the waveform transitions.

Reduced Voltage Motor Starting Panels by Reactors

Reduced Voltage Motor Starting Panels by Reactors

A method to limit motor starting current is a series reactor. Iron core or air core reactors can be used for starting purposes. If an air core is used for the series reactor then a very efficient and reliable soft starter can be designed which is more suitable for high MW ratings of synchronous/induction motors .

Engineering Bulletin - Starters, Drives, and Electrical .

Engineering Bulletin - Starters, Drives, and Electrical .

Electric, centrifugal, water-cooled chillers use relatively large induction motors to drive the compressors. These motors use a co ntrol device to connec t to and disconnect from the electrical power source. These control device s are referred to as combinatio n controllers or, most commonly, as motor starters.

Comparison Between AC Reactor and DC Link Choke | EMA Inc.

Comparison Between AC Reactor and DC Link Choke | EMA Inc.

Thereby extending the life span of the drive, and improving the drive's True Power Factor. Reactors for VFD's are sold as either AC reactors or DC reactors (also called link chokes). Both reactor types serve the same primary purpose, to smooth the current flow to the VFD, and reduce damaging harmonics produced on the power line.

Air core motor starting reactor – definition

Air core motor starting reactor – definition

Air core motor starting reactor – definition Search for your solution. An air core reactor that starts motors at a reduced voltage. What are Motor Starting Autotransformers?

Motors and Drives, Inc.

Motors and Drives, Inc.

Motors & Drives, Inc. has been Servicing the Casino Industry for 20yrs. Repair, Rewind or Replacement of your Motors, Pumps, Reducers & Baldor Drives. Computerized Laser Alignment Equipment Computerized Balancing Equipment Surge Analysis Equipment.

Motors and Drives - Parr Instrument Company

Motors and Drives - Parr Instrument Company

Air Motors. Air-driven motors can be installed on most reactors. The horsepower rating, torque, and available speed are all dependent upon the pressure and available volume of the driving air source. Maximum torques are delivered at relatively slow speeds and maximum horsepower is delivered at high speed. Geared, Direct Drive Motors

Plant Engineering | When it comes to motors, how hot is hot?

Plant Engineering | When it comes to motors, how hot is hot?

Sep 10, 2013 · Unfortunately, air for cooling was drawn through the radiator and then exhausted by a fan on the drive motor. With this arrangement, ambient temperatures in the enclosures reached 70 C, thermally stressing the motor winding insulation to its limit. Overheated lubricant also evacuated bearing housings, causing numerous bearing failures .

Reactors - processdesign

Reactors - processdesign

Mixing is conducted by an impeller mounted on a shaft driven by a motor. The reactor usually contains baffles or other internals to induce turbulence and prevent the contents from swirling and creating a vortex. Typically, baffles are 1/10 of diameter and located 1/20 of diameter from wall (Towler, 2012).

Why Should You Use a Line Reactor?

Why Should You Use a Line Reactor?

Line reactors features . As you know, AC line reactors applied to the line side of a VFD drive will improve THID and provide increased reliability and longevity. Our line reactors currently begin at 74.99. View our list of inventory here: Specifications: Sizes from 1/2 HP to 1250 HP; 3 phase, 600V class; Available in 208/240, 480 and 575/600 .

Industrial Mixers: Air, Electric, Motor & More - Cole-Parmer

Industrial Mixers: Air, Electric, Motor & More - Cole-Parmer

Industrial mixers are used for mixing large quantities of material, or materials with higher viscosities and torque requirements. With the right mixer and propeller, industrial mixers can mix up to 1500 gallons (5700 liters) of material with a viscosity of 1000 cps.

Electrical Reactor: What are They? (Line Reactors .

Electrical Reactor: What are They? (Line Reactors .

Mar 15, 2020 · What is a Line Reactor? A line reactor (also referred to as an electrical reactor or a choke) is a variable frequency drive (VFD) accessory that consists of a coil of wire that forms a magnetic field as current flows through it. This magnetic field limits the rate of rising of the current, thus reducing harmonics and protecting the drive from power system surges and transients.

Plant Engineering | When it comes to motors, how hot is hot?

Plant Engineering | When it comes to motors, how hot is hot?

Sep 10, 2013 · Unfortunately, air for cooling was drawn through the radiator and then exhausted by a fan on the drive motor. With this arrangement, ambient temperatures in the enclosures reached 70 C, thermally stressing the motor winding insulation to its limit. Overheated lubricant also evacuated bearing housings, causing numerous bearing failures .

CALCULATING PERCENT IMPEDANCE FOR AC LINE REACTOR

CALCULATING PERCENT IMPEDANCE FOR AC LINE REACTOR

Calculate the percent impedance for a reactor that has a per phase inductance of .001475 Henries that is used on a drive with 16 A of input current flowing at 480 V and at a 60 Hz fundamental frequency. %Z = .001475 / [(480 / 1.732) / (16 x 2 x 3.14 x60)] x .001475 / (277.14 / 6031.86) x .001475 / .04595 x 3.2 %

Drum Agitators - Graco

Drum Agitators - Graco

Rotary vane air motors are known for durability and a low initial cost.These pneumatic agitator motors run the most efficiently at medium to high speeds. Radial piston air motors consume 30 to 50 percent less air than rotary vane motors.Manufacturers with moderate budgets can easily upgrade to radial piston agitators, which run the most efficiently at low to medium speeds.

30-50L Reactor Systems- Chemglass Life Sciences

30-50L Reactor Systems- Chemglass Life Sciences

50l process reactors, cylindrical, jacketed, electric or air motor. from 20,254.95. cg-1968 cg-1970 50l jacketed squatty 50l process reactors, cylindrical, jacketed, squatty, electric or air motor. from 0.00. cg-1972 cg-1974 30l unjacketed . powered by nopcommerce .

What is a Line Reactor?

What is a Line Reactor?

A line reactor (also referred to as a "choke") is a variable frequency drive (VFD) accessory that consists of a coil of wire that forms a magnetic field as current flows through it. This magnetic field limits the rate of rise of the current, thus reducing harmonics and protecting the drive .

How Inverters Work Basics | HVAC Heating and Cooling

How Inverters Work Basics | HVAC Heating and Cooling

How Inverters Work Basics - The new way for ultra efficient air conditioners and heat pumps is modulating compressors and motors. A few years ago it was rare that I got an email asking the question about how inverters work but now I have noticed the question coming more and more so I wanted to write an article to explain how inverters work.

Current Limiting Reactor | L/C Magnetics

Current Limiting Reactor | L/C Magnetics

L/C Magnetics Is A Manufacturer Of Current Limiting Reactors (Clr). Current-Limiting Reactors Are Series Inductors Intended To Reduce The Short Circuit Currents Passing Thru The Circuit Breaker In The Power System. A Higher Voltage Is Developed Across The .

TR200 Series - Variable Frequency Drives

TR200 Series - Variable Frequency Drives

frequency drive, the TR200 Series, is an example of this commitment. Today more than ever, facility professionals are required to use a range of strategies for energy efficiency. A variable frequency drive is an electronic system that provides infinitely variable speed control of three-phase AC induction motors.

URC II Mini - Universal Reactor Controller | Parker .

URC II Mini - Universal Reactor Controller | Parker .

The URC II Mini Controller is an integrated package utilizing a Programmable Logic Controller (PLC) for all process control, monitoring and coordination in conjunction with a touch screen operator display unit. The URC II Mini provides the operator with a concise point of control for all processes related to a reactor system. The unit controls and monitors the reactor's external and internal .

Variable Frequency Drives Troubleshooting

Variable Frequency Drives Troubleshooting

Drop motor leads and verify output voltage phase-to-phase. Roll motor leads (be particularly concerned about reversing the motor). Does the issue follow the motor lead or stay in the same phase? Conduit box: Taping, connections, and skinned wires/connection. Grounding. Motor: If output voltages are balanced, then direct attention to motor.

Stirrer Options - Parr Instrument Company

Stirrer Options - Parr Instrument Company

Turbine Type Impellers Parr reactors are usually equipped with turbine type impellers which produce an excellent mixing action over the range of stirring speeds at which these reactors typically operate. These impellers are made in four- blade and six-blade styles, with the smaller four-blade impellers used only on Micro and Mini Reactors. These impellers, for [.]