Our Products

Rotary Evaporator

Laboratory equipment

Jacketed Reactor

Contact Us

We Cherish All Interactions

Comparative toxicity profiles of Plumbago zeylanica L .

Comparative toxicity profiles of Plumbago zeylanica L .

The roots were shade dried and ground into a coarse powder. The plant material was then packed into a thimble and subjected to successive continuous Soxhlet extraction with petroleum ether, acetone, and 70% ethanol. The solvents were evaporated under vacuum, using a rotary evaporator to get respective semisolid extracts.

Simultaneous Analysis of Fat-Soluble Vitamins A, D, and E .

Simultaneous Analysis of Fat-Soluble Vitamins A, D, and E .

Note: If only vitamin A and _-tocopherol are to be assayed, petroleum ether can be used as the extractant. Concentration n The washed ether layer was dried with anhydrous sodium sulfate (about 3 g), then filtered into a 250 mL rotary evaporation flask or a nitrogen evaporator .

Preliminary Screening of Antibacterial Activity Using .

Preliminary Screening of Antibacterial Activity Using .

The collected plants were dried in the oven (40°C), ground into a course powder and stored at −20°C. The dried, powdered leaves and stem were extracted using petroleum ether, ethyl acetate and methanol by cold extraction. The extract was filtered and concentrated to a small volume to remove all the solvent using a rotary evaporator at 40°C.

Separation of Compounds Using Column Chromatography .

Separation of Compounds Using Column Chromatography .

Remove the solvent by placing the mixture in a rotary evaporator at a low temperature. Place the dry powder on a piece of weighing paper and transfer it to the top of the column through the funnel. Developing the Chromatogram: Attach a dropping funnel filled with petroleum ether on to the column.

Simple Accordion with CSS & jQuery by Soh Tanaka

Simple Accordion with CSS & jQuery by Soh Tanaka

After the addition is complete, the ether is removed on a rotary evaporator. The solid residue is dissolved in 800 ml. of hot chloroform. To this solution is added, with gentle stirring, 150 ml. of hot petroleum ether (b.p. 60–90°).

How can i evaporate a solvent without rotary

How can i evaporate a solvent without rotary

I will be extracting using methanol as a solvent and I am trying to figure another way of removing methanol from my plant extracts except via a rotary evaporator.

LESSON LEARNED Peroxide Explosion Injures Campus .

LESSON LEARNED Peroxide Explosion Injures Campus .

was using a rotary evaporator (rotovap) to remove organic solvents from an azobenzene precipitate. She adjusted the bottom flask which then exploded sending glass towards her face, hitting her safety goggles and forehead. Lab personnel helped her to the safety shower and .

Green Synthesis of Iron Nanoparticles: Application on the .

Green Synthesis of Iron Nanoparticles: Application on the .

Lastly, the extract was concentrated on a rotary evaporator (Buchi-850) removing the solvent. 2.2.2. Polyphenol and Antioxidant Capacity Tests. The polyphenol concentration of the extract was found with the Folin–Ciocalteu method. Briefly, the extract was sonicated on a CV33-Daigger ultrasonic processor and concentrated on a rotary evaporator.

Organic Chemistry Triphenylmethanol Grignard Lab T .

Organic Chemistry Triphenylmethanol Grignard Lab T .

Question: Organic Chemistry Triphenylmethanol Grignard Lab The Data You May Need Is: 2.72 G Of The Product Were Collected, Mel-Temp Was 161.5 - 163.0 OC. Read The Instructions For The Lab (file Attached). Visualize Yourself Doing The Lab. Complete The Triphenylmethanol Data Sheet (file Attached), Assuming That 2.72 G Of The Product Were Collected And That Your .

Petroleum Ether - an overview | ScienceDirect Topics

Petroleum Ether - an overview | ScienceDirect Topics

A mix butanol/ petroleum ether /ethyl acetate is used to separate the organic phase containing the acyl chains from the aqueous phase containing the [3 H]glycerophosphoinositides (gPIs). 1. Prepare a mix C 4 H 9 OH:C 6 H 14:C 4 H 8 O 2 (20:4:1).. 2. Add 600 μl mix/sample. 3. Add 500 μl of distilled water/sample. 4. Vortex. 5. Centrifuge (2500 rpm, 1 min, room temperature).

Rotary evaporator - Wikipedia

Rotary evaporator - Wikipedia

A rotary evaporator (or rotavap /rotovap) is a device used in chemical laboratories for the efficient and gentle removal of solvents from samples by evaporation.When referenced in the chemistry research literature, description of the use of this technique and equipment may include the phrase "rotary evaporator", though use is often rather signaled by other language (e.g., "the sample was .

Evaporating solvents with Nitrogen (2013 version)

Evaporating solvents with Nitrogen (2013 version)

Oct 30, 2013 · WORLD'S BEST TREE FELLING TUTORIAL! Way more information than you ever wanted on how to fell a tree! - Duration: 45:25. Guilty of Treeson Recommended for you

Isolation of Caffeine from Tea - Chem21Labs

Isolation of Caffeine from Tea - Chem21Labs

10 drops low-boiling petroleum ether (primarily pentane) to precipitate caffeine from the solution. If caffeine does not precipitate, heat the solution on a hot plate to remove ~ 0.25 mL acetone and add 10 more drops of low-boiling petroleum ether. Keep removing 0.25 mL of acetone and adding the petroleum ether until crystals form.

Isoflavanones, and Sugar-Based Chiral Analogues Annulation .

Isoflavanones, and Sugar-Based Chiral Analogues Annulation .

then the organic layer was dried over Na2SO4 and the solvent was removed in a rotary evaporator under reduced pressure at room temperature. The crude product was purified by column chromatography on silica gel (60-120 mesh) using ethyl acetate and petroleum ether (1:10) to afford pure O-alkylmonoacetonidenitroolefine in 85-90% yield. 2.

Glassware For Petroleum Suppliers, Manufacturer .

Glassware For Petroleum Suppliers, Manufacturer .

Alibaba offers 10 Glassware For Petroleum Suppliers, and Glassware For Petroleum Manufacturers, Distributors, Factories, Companies. There are 1 OEM, 1 ODM, 2 Self Patent. Find high quality Glassware For Petroleum Suppliers on Alibaba.

Effect of different solvent extracted sample of Allium .

Effect of different solvent extracted sample of Allium .

the upper petroleum ether phase (petroleum ether being lighter than water) were collected and the lower aqueous phase was extracted thrice with petroleum ether. All fractions of petroleum ether were combined and poured into round bottom flask of rotary evaporator and petroleum ether .

PEER-REVIEWED ARTICLE bioresources

PEER-REVIEWED ARTICLE bioresources

chloride > methanol > petroleum ether > n-hexane. Based on their extraction yield, an efficient solvent combination of n-hexane, ethyl . evaporated under reduced pressure in a rotary evaporator to completely remove the solvent. The substance left was considered bio-oil. The extractability of bio-oil was calculated with the following equation:

Experiment 2 Flashcards | Quizlet

Experiment 2 Flashcards | Quizlet

Diethyl ether, petroleum ether, methylene chloride. disposed of in containers labeled Liquid Organic Waste. . -remove the blue clip and slowly twist off the flask-leave the flask uncorked. . evaporation by rotary evaporator. What is the point of fluted filter paper. folding filter paper provides a lot of SA on which to trap the solid impurity

Chemical Glassware Chemistry Laboratory Solvent . - Alibaba

Chemical Glassware Chemistry Laboratory Solvent . - Alibaba

Chemical Glassware Chemistry Laboratory Solvent Extraction Equipments Vacuum Distillation Solvent Evaporator, Find Complete Details about Chemical Glassware Chemistry Laboratory Solvent Extraction Equipments Vacuum Distillation Solvent Evaporator,Mini Alcohol Soxhlet Extractor,Rotary Evaporator For Removing Petroleum Ether,Solvent Extraction In Chemistry from Evaporator Supplier or .

7. Lipids Flashcards | Quizlet

7. Lipids Flashcards | Quizlet

- petroleum ether and diethyl ether - centrifugation (decant ether into weighed dish) - evaporation. Reagents of majonnier - NH4OH - Ethanol - Diethyl ether - petroleum ether. NH4OH . - remove CHCl3. Infrared Method - fat can absorb IR energy at 3.73um - more energy absorption, higher fat content of sample .

Two-Dimensional HPLC Separation of Vitamin D in Feedstuff

Two-Dimensional HPLC Separation of Vitamin D in Feedstuff

(anhydrous) to remove the residual water. Let the petroleum ether and Na 2 SO 4 mixture stand in the 500 mL separatory funnel until fully layered, then release the subnatant to remove Na 2 SO 4 from the petroleum ether. Using rotary evaporation at 55 °C, condense the volume of petroleum ether extract to ~2 mL. Transfer the

Isolation of Caffeine from Tea - Chem21Labs

Isolation of Caffeine from Tea - Chem21Labs

10 drops low-boiling petroleum ether (primarily pentane) to precipitate caffeine from the solution. If caffeine does not precipitate, heat the solution on a hot plate to remove ~ 0.25 mL acetone and add 10 more drops of low-boiling petroleum ether. Keep removing 0.25 mL of acetone and adding the petroleum ether until crystals form.

Petroleum Ether - an overview | ScienceDirect Topics

Petroleum Ether - an overview | ScienceDirect Topics

A mix butanol/ petroleum ether /ethyl acetate is used to separate the organic phase containing the acyl chains from the aqueous phase containing the [3 H]glycerophosphoinositides (gPIs). 1. Prepare a mix C 4 H 9 OH:C 6 H 14:C 4 H 8 O 2 (20:4:1).. 2. Add 600 μl mix/sample. 3. Add 500 μl of distilled water/sample. 4. Vortex. 5. Centrifuge (2500 rpm, 1 min, room temperature).

Your Evaporation Guide Operation Rotation speed

Your Evaporation Guide Operation Rotation speed

Figure 1: First generation rotary evaporator (BUCHI Rotava-por, Model 1957). Even nowadays, evaporation and distillation are still one of the most frequently used separation methods. In fact, the evaporation output of a rotary evaporator during single-stage distillation is around four times greater than that of conventional, static distillation .

Antimicrobial potentials of Eclipta alba by disc diffusion .

Antimicrobial potentials of Eclipta alba by disc diffusion .

upper petroleum ether phase (petroleum ether being lighter than water) were collected and the lower aqueous phase was extracted thrice with petroleum ether. All fractions of petroleum ether were combined and poured into round bottom flask of a rotary evaporator and petroleum ether was isolated from the fraction leaving behind

Triphenylmethanol Grignard Lab Read The Instructio .

Triphenylmethanol Grignard Lab Read The Instructio .

Remove the (diethyl) ether, which boils at a lower temperature than the petroleum ether, by means of rotary evaporation. Triphenylmethanol precipitates from the petroleum ether while the biphenyl impurity remains in solution. Cool the slurry, filter the solid, and wash the crystals with cold petroleum ether.

Department of Chemistry, ICSTM: Advanced Organic Chemistry

Department of Chemistry, ICSTM: Advanced Organic Chemistry

Separate the ether layer and extract the aqueous layer with ether (2 x 15 ml). Wash the combined ethereal extracts with saturated sodium carbonate solution then with water, dry (MgSO4) and evaporate the ether using a rotary evaporator. Distil the residue at the oil pump and record the ir .

Teaching an Old Poly(arylene ether) New Tricks: Efficient .

Teaching an Old Poly(arylene ether) New Tricks: Efficient .

After the solvent removal by a rotary vacuum evaporator, the residue was purified by silica-gel column chromatography, with petroleum ether/ethyl acetate (v/v 12:1) as the eluent, to give a white solid 4 (40.73 g, 84%). 1H NMR (400 MHz, CDCl3, δ ppm): 7.95 (d,

Chemical Glassware Chemistry Laboratory Solvent . - Alibaba

Chemical Glassware Chemistry Laboratory Solvent . - Alibaba

Chemical Glassware Chemistry Laboratory Solvent Extraction Equipments Vacuum Distillation Solvent Evaporator, Find Complete Details about Chemical Glassware Chemistry Laboratory Solvent Extraction Equipments Vacuum Distillation Solvent Evaporator,Mini Alcohol Soxhlet Extractor,Rotary Evaporator For Removing Petroleum Ether,Solvent Extraction In Chemistry from Evaporator Supplier or .

Working with Hazardous Chemicals

Working with Hazardous Chemicals

removed on a rotary evaporator until a slurry results (Note 13). The slurry is diluted with 200 mL of petroleum ether (bp 60–68°C), and the supernatant solution is decanted and filtered through 150 g of Celite on a Büchner funnel. The solids remaining in the flask are heated with three 100-mL portions of