Our Products

Rotary Evaporator

Laboratory equipment

Jacketed Reactor

Contact Us

We Cherish All Interactions

Understanding Vacuum Measurement Units

Understanding Vacuum Measurement Units

(Fig. 2) Initially, with the shut-off and air-admit valves open and the vacuum pump switched off the mercury level in the glass tube would be at the same level as the rest of the mercury in the container. The system is all at atmospheric pressure. When the shut-off and air admit valves are closed and the vacuum pump switched on the vacuum line .

Air Conditioning Vacuum Pump

Air Conditioning Vacuum Pump

Air Conditioning Vacuum Pump. Air conditioning vacuum pump is used to remove unwanted air and water vapor from the air conditioning system when it is under service. When the air conditioner needs to be repaired, the first step taken is usually to recover the refrigerant from the system for reuse later.

Vacuum Pumps -

Vacuum Pumps -

Product Title ZENSTYLE Combo 3,5CFM 1/4HP Air Vacuum Pump HVAC + R . Average rating: 3 out of 5 stars, based on 2 reviews 2 ratings Current Price 94.99 94 . 99 List List Price 158.32 158 . 32

HVAC How To – HVAC How-To, Tutorials, Reviews, Information .

HVAC How To – HVAC How-To, Tutorials, Reviews, Information .

Vacuum pumps are a necessary part of HVAC to get a system into a vacuum and even test for leaks. The most common use is to pump down a line-set and then let it sit to see if there are any leaks. A/C system require a vacuum to work correctly which a good vacuum pump. Read More »

Valuetesters.com | AC Vacuum Pump | HVAC AC - On Sale!

Valuetesters.com | AC Vacuum Pump | HVAC AC - On Sale!

Water Quality Testing; Weather Instruments; HVAC AC. Air Flow Capture Hood; Smart Probes; Digital Manifold Gauge Sets; Electronic Vacuum Gauge; AC Vacuum Pump; Refrigerant Recovery Machine; Analog Manifold Gauge Sets; Charging Manifold; AC Manifold Gauge; HVAC Analyzer; Air Velocity Meter; Dye Leak Detector; CFM Anemometer; Heater Blanket; HVAC .

Evacuation and Vacuum Training - HVAC and Energy Auditing .

Evacuation and Vacuum Training - HVAC and Energy Auditing .

System Evacuation / Vacuum Training for Air Conditioning and Refrigeration . After the second standing test, allow the vacuum pump to run until the system is preferably below 200 microns. (With a good pump 50-100 microns is easily achievable.) Isolate the vacuum rig with the core tools and allow the system to stand for 15 to 30 minutes.

Best Vacuum Pump Reviews and Complete buying Guide

Best Vacuum Pump Reviews and Complete buying Guide

The best vacuum pump has many uses, but basically what it does is maintain system pressure. A few examples of how you can use this device: HVAC: Vacuum pumps are often used to repair HVAC or A/C systems. They are in fact used by professional technicians. Sewerage Systems: Vacuum pumps are also used in some sewer systems to keep pressure levels .

How To Choose The Right Vacuum Pump - Choosing The Pump .

How To Choose The Right Vacuum Pump - Choosing The Pump .

Recommended Oil Filled Rotary Vane Vacuum Pumps: 3-CFM Single Stage Vacuum Pump - 2424 Models. 5-CFM Two-Stage Vacuum Pump - 2424 & 3624 Models. 8-CFM Two-Stage Vacuum Pump - 2424 & 3624 Models. Other considerations. If you purchase one of our pre converted vacuum pumps, you don't need to do anything else.

The Best Vacuum Pumps (Review) in 2020 | Car Bibles

The Best Vacuum Pumps (Review) in 2020 | Car Bibles

This CFM Vacuum pump is a lightweight HVAC vacuum pump, developed and built with premium materials which are both robust and durable. For the performance which significantly resembles a two-stage performance system, the CFM Vacuum pump employs the Twin Port Technology and a single-stage pump system for better efficiency and improved performance.

Yellow Jacket Vacuum Pump Systems - at Test Equipment Depot

Yellow Jacket Vacuum Pump Systems - at Test Equipment Depot

Providing the finest test equipment solutions since 1992. Catalog; Clearance; Promotions; Refurbished; Government; Education; Contact; HOME > YELLOW-JACKET > VACUUM-PUMP-SYSTEMS > INDEX Yellow Jacket Vacuum Pump Systems. 3 CFM Vacuum Pumps. 4 CFM Vacuum Pumps. 5 CFM Vacuum Pumps. 6 CFM Vacuum Pumps. 7 CFM Vacuum Pumps. 8 CFM Vacuum Pumps. 11 .

System holds pressure test, but can't pull a vacuum? : HVAC

System holds pressure test, but can't pull a vacuum? : HVAC

Remember, vacuum pumps are pretty decent/quick at getting air out of a system (although at 38 tons it is still going to take a while) but not so quick at getting the moisture. So, I'd run the pump until it stalls, and nitrogen sweep for a while and just keep repeating that cycle.

Air Conditioning Vacuum Pump

Air Conditioning Vacuum Pump

Air Conditioning Vacuum Pump. Air conditioning vacuum pump is used to remove unwanted air and water vapor from the air conditioning system when it is under service. When the air conditioner needs to be repaired, the first step taken is usually to recover the refrigerant from the system for reuse later.

Featured HVAC Vacuum Pumps - at Test Equipment Depot

Featured HVAC Vacuum Pumps - at Test Equipment Depot

Featured HVAC Vacuum Pumps at Test Equipment Depot. Robinair 15300 VacuMaster Economy 3 CFM Vacuum Pump, 1/3 hp, 7.5 oz Oil Capacity, 115V/60 Hz

How To Vacuum Down a Mini Split and Release . - HVAC How To

How To Vacuum Down a Mini Split and Release . - HVAC How To

Hook Center Yellow Hose to the Vacuum Pump. Turn On the vacuum pump and open the valve on the HVAC Gauges Low Pressure Side (Blue). Let the pump run until it goes into a Vacuum, negative pressure. Let the pump run for at least 15-20 minutes or more and turn the Blue valve on the gauges shut, and then the vacuum pump off.

NAVAC Inc. - HVAC and Energy Auditing Tool Sales | Testo

NAVAC Inc. - HVAC and Energy Auditing Tool Sales | Testo

NAVAC makes it possible for HVAC technicians to complete jobs with more accuracy, ease, and efficiency. Available at TruTech Tools!

HVAC Full Vacuum Procedure From Start to Finish!

HVAC Full Vacuum Procedure From Start to Finish!

May 30, 2018 · Our Book https:// In this HVACR Training Video, I go over how to Perform a Fast and Deep Vacuum for Dehydration of an Air Condi.

Refrigerant Recovery Equipment, HVAC Vacuum Pumps, Hoses .

Refrigerant Recovery Equipment, HVAC Vacuum Pumps, Hoses .

HVAC/R Product Categories. Well-engineered refrigerant recovery equipment, HVAC vacuum pumps, HVAC hoses and refrigerant gauges for your exacting standards.

HVAC Unit 8 Flashcards | Quizlet

HVAC Unit 8 Flashcards | Quizlet

It is not required by the EPA to repair systems that contain less than _____ lb of refrigerant. For industrial processes equipment and commercial refrigeration equipment, systems that contain more than _____ lb of refrigerant must be repaired when the leak rate is more than _____% of their total charge in 1 year.

Our Picks for Best HVAC Vacuum Pumps – HVAC How To

Our Picks for Best HVAC Vacuum Pumps – HVAC How To

Mar 02, 2020 · HVAC Vacuum pumps can be bought in 1-2 stage units. 1-stage units do not pull a vacuum as well as 2-stage units and are not as widely used anymore. Single stage pumps would be good as a backup unit or for a part-time HVAC tech. 2-stage vacuum pumps can pull a much deeper vacuum and are the most widely used pumps used in HVAC.

Test PSI HVAC/R Vacuum Pumps for sale

Test PSI HVAC/R Vacuum Pumps for sale

Test Digital HVAC/R Vacuum Pumps. Make an Offer. HVAC Tool Kit:Rotary Vacuum Pump+Manifold Gauge+Hose+Leak Detector+R134a Coupler. 227.77. Free shipping. Make Offer - HVAC Tool Kit:Rotary Vacuum Pump+Manifold Gauge+Hose+Leak Detector+R134a Coupler. Combo 5CFM 1/3HP Air Vacuum Pump HVAC + R134A AC A/C Dual Manifold Gauge Set R22.

Compressor efficiency test - hvac machinery

Compressor efficiency test - hvac machinery

Dec 06, 2015 · Compressor efficiency test This is also referred to as a compressor pump test. It is carried out when the functions of the compressor suction and discharge valves are suspect; this will be indicated by high suction and low discharge pressures. The test should be carried out with the plant running at an operating head pressure.

How to Pull the Vacuum on a Heat Pump | eHow

How to Pull the Vacuum on a Heat Pump | eHow

Turning the vacuum pump off before shutting the manifold valves will cause the the heat pump to suck the oil out of the vacuum pump, contaminating the system. Step 4 Disconnect the yellow hose from the electronic vacuum gauge and connect it to the nitrogen bottle. Open the valve on the nitrogen, then open the manifold valves to break the vacuum.

Evacuation Procedure - HVAC Know It All

Evacuation Procedure - HVAC Know It All

Nov 25, 2017 · Use the reading on the micron gauge to determine when a proper vacuum has been achieved. It is common within the industry to set a vacuum target of 500 microns. 8. Once the target vacuum has been achieved, isolate the system from the pump and observe the micron gauge reading. A common term for this procedure is called a "decay test".

AC Vacuum Pump - Automotive Vacuum Pump for AC

AC Vacuum Pump - Automotive Vacuum Pump for AC

OEM OEMTOOLS Premium Vacuum Pump Oil 7.4oz. You have 0 Items In Your Cart. CART TOTAL: 0 00. VIEW CART AND CHECKOUT. Home ∕ Tools and Equipment ∕ Test, Scan And Specialty Tools ∕ Air Conditioning Testing, Scanning and Specialty Tools .

A/C R134A Manifold Gauge Set - Harbor Freight Tools

A/C R134A Manifold Gauge Set - Harbor Freight Tools

This A/C Manifold Gauge Set is designed to test automotive air conditioning systems (using R134A refrigerant only) by comparing the "high side" and "low side" pressure reading to the vehicle manufacturer's A/C system specifications. This A/C Manifold Gauge Set can be used to test, evacuate and fill automotive air conditioning systems.

Leak testing by vacuum. - HVAC-Talk: Heating, Air .

Leak testing by vacuum. - HVAC-Talk: Heating, Air .

May 03, 2010 · It seems to me that a vacuum test is still a pressure test but your test pressure is only 14.7 psi (at sea level). Vacuum test is the big thing where I work, and if somebody convinces me I should . a non-DIY site and the ultimate Source for HVAC Information & Knowledge Sharing for the industry professional! . and the biggest vacuum pump you .

NAVAC HVAC Vacuum Pumps | TEquipment

NAVAC HVAC Vacuum Pumps | TEquipment

NAVAC HVAC Vacuum Pumps A vacuum pump is used to remove air and contaminants from an HVAC system after refrigerant recovery. This creates a vacuum state. The deeper and more complete the vacuum, the more contaminants trapped within the system, its components, and even the compressor oil are removed.

Test R-134a Refrigerant HVAC/R Vacuum Pumps for sale

Test R-134a Refrigerant HVAC/R Vacuum Pumps for sale

Test R-22 Refrigerant HVAC/R Vacuum Pumps. Make an Offer. Refrigerantion Manifold Digital Gauge Meter HVAC Vacuum Pressure Temp Tester. 159.99. Free shipping. Make Offer - Refrigerantion Manifold Digital Gauge Meter HVAC Vacuum Pressure Temp Tester. HVAC Tool Kit:Rotary Vacuum Pump+Manifold Gauge+Hose+Leak Detector+R134a Coupler.

The Best Vacuum Pumps (Review) in 2020 | Car Bibles

The Best Vacuum Pumps (Review) in 2020 | Car Bibles

This CFM Vacuum pump is a lightweight HVAC vacuum pump, developed and built with premium materials which are both robust and durable. For the performance which significantly resembles a two-stage performance system, the CFM Vacuum pump employs the Twin Port Technology and a single-stage pump system for better efficiency and improved performance.

Robinair HVAC/R | Portable Recovery Units | Vacuum Pumps

Robinair HVAC/R | Portable Recovery Units | Vacuum Pumps

Robinair vacuum pumps are engineered to increase productivity through fast and complete air and moisture removal. Backed by a limited, no-hassle replacement warranty, they feature a lightweight design for fast, portable use.