Our Products

Rotary Evaporator

Laboratory equipment

Jacketed Reactor

Contact Us

We Cherish All Interactions

6L Low Temperature Cooling Liquid Circulator Pump Chiller .

6L Low Temperature Cooling Liquid Circulator Pump Chiller .

Low Temperature Cooling Liquid Circulator 6L. The refrigeration system has over-heating and over-current multiple protective function. To improve the service life of the refrigeration system, the system adopt startup protection.

Small glycol chiller low temp Circulating Cooler coolant pump

Small glycol chiller low temp Circulating Cooler coolant pump

5L -10C small electric water circulating coolant pump . The HAOCHENG coolant pump are designed to provide a continuous supply of fluid at a constant temperature and volume. This unit offers a refrigeration system, heat exchanger, imported recirculating pump, 1Cr18Ni9Ti reservoir, and a microprocessor temperature controller. These pump offer the following features:

Low Temperature Circulator at Thomas Scientific

Low Temperature Circulator at Thomas Scientific

JULABO Ultra-low refrigerated circulators for heating and cooling are suitable for external temperature tasks. Powerful circulating pump systems and high heating and cooling capacities guarantee short heat-up and cool-down times. ACC 'Active Cooling Control' provides active cooling.

-30º C Low Temperature Cooling Water Circulating Pump

-30º C Low Temperature Cooling Water Circulating Pump

Ancillary Equipment of Low-twmperature Circulating Pump: Cooling liquid circulating pump is usually used as ancillary equipment of rotary evaporator, glass reactor, short path distillation,the main function is providing low temperature liquid for condensation or low temperature reaction. FAQ: 1.What's the max temperature? We have the lowest temperautre -10ºC,-30ºC,-40ºC,-120ºC.

HNZXIB Small Capacity Lab Low Temp Cooling Liquid .

HNZXIB Small Capacity Lab Low Temp Cooling Liquid .

The low temperature coolant circulation pump adopts air-cooled fully enclosed compressor unit refrigeration and microcomputer intelligent control system to provide low temperature cooling water to meet the cooling or constant temperature instrument with cooling water or cryogenic liquid. Its main function is low temperature reaction and .

HNZXIB Small Capacity Lab Low Temp Cooling Liquid .

HNZXIB Small Capacity Lab Low Temp Cooling Liquid .

The low temperature coolant circulation pump adopts air-cooled fully enclosed compressor unit refrigeration and microcomputer intelligent control system to provide low temperature cooling water to meet the cooling or constant temperature instrument with cooling water or cryogenic liquid. Its main function is low temperature reaction and .

COOLANT CIRCULATION PUMP - Phillips & Temro Industries

COOLANT CIRCULATION PUMP - Phillips & Temro Industries

COOLANT CIRCULATION PUMP Customer service: Toll Free: 800.328.6108 Email: [email protected] The Coolant Circulation Pump increases coolant flow in the Arctic Fox™ Fuel and Fluid Temperature Management Systems. WHERE TO USE • Multiple heat exchangers are installed • Remote tank installations that .

Low Temperature Pump | Low Temp Pump | Coolant Pump

Low Temperature Pump | Low Temp Pump | Coolant Pump

LOW TEMPERATURE-MP-MPL SERIES. ANSI; Excellent For Low Temperature Service; Max Flow: 2000 GPM; Max Head: 470 Feet; Temperature: -150°F to 800°F

Laboratory Low temperature cooling liquid water .

Laboratory Low temperature cooling liquid water .

Mar 01, 2019 · DLSB-5 series low-temperature cooling liquid circulating pump, also known as low temperature pump, low temperature circulating pump, low temperature cooling water circulating pump, water tank .

China Low Temperature Coolant Circulation Chiller Pump .

China Low Temperature Coolant Circulation Chiller Pump .

• Adopt full closed circulation design, no water vapor at low temperature and ensure the purity of cooling medium in case of ice crystals, provide a long time life of heat transfer liquid. • High-performance circulating pump, can guarantee 24 hours' continuously running a day.

DLSB-5 Series Low Temperature Cooling Liquid Circulating Pump

DLSB-5 Series Low Temperature Cooling Liquid Circulating Pump

Low temperature coolant circulation pump with constant current and voltage, circulating fluid can meet the electron microscopy, electric probe, ultra-high vacuum sputtering, X-ray machines, lasers, accelerators and other valuable equipment's need of cooling. For the purification of high purity metals, rare elements, environment experiment and .

China Dlsb-30/30 Refrigerated Circulating Chiller Low .

China Dlsb-30/30 Refrigerated Circulating Chiller Low .

Ancillary Equipment of Low-twmperature Circulating Pump: Cooling liquid circulating pump is usually used as ancillary equipment of rotary evaporator, glass reactor, short path distillation,the main function is providing low temperature liquid for condensation or low temperature reaction. FAQ: 1.What's the max temperature? We have the lowest temperautre -10ºC,-30ºC,-40ºC,-120ºC.

Cooling tower - Wikipedia

Cooling tower - Wikipedia

A cooling tower is a heat rejection device that rejects waste heat to the atmosphere through the cooling of a water stream to a lower temperature. Cooling towers may either use the evaporation of water to remove process heat and cool the working fluid to near the wet-bulb air temperature or, in the case of closed circuit dry cooling .

Circulator pump - Wikipedia

Circulator pump - Wikipedia

A circulator pump or circulating pump is a specific type of pump used to circulate gases, liquids, or slurries in a closed circuit. They are commonly found circulating water in a hydronic heating or cooling system. Because they only circulate liquid within a closed circuit, they only need to overcome the friction of a piping system (as opposed to lifting a fluid from a point of lower potential .

Circulator Pumps | Grundfos

Circulator Pumps | Grundfos

The ALPHA 15-55 HWR-D is a recirculation system that delivers hot water in homes at the push of a button and can save thousands of gallons of water each year. The system includes an ALPHA 15-55 circulator pump (with a permanent magnet motor), a temperature sensor and two push button controls. Literature - General Brochure

China Low Temperature Cooling Liquid Circulating Pump .

China Low Temperature Cooling Liquid Circulating Pump .

China Low Temperature Cooling Liquid Circulating Pump Chiller, Find details about China Lab Chiller, Recirculating Chiller from Low Temperature Cooling Liquid Circulating Pump Chiller - Zhengzhou Well-Known Instrument and Equipment Co., Ltd.

DLSB Cooling chiller machine system

DLSB Cooling chiller machine system

- The circulatory system is made of anti-corrosion material and has functions such as anti-rust, anti-corrosion, and low-temperature liquid pollution sterilization. - The circulation pump can output the cold liquid in the tank, cool or cool the outside of the experimental container or establish a second constant-temperature field.

Cooling tower - Wikipedia

Cooling tower - Wikipedia

A cooling tower is a heat rejection device that rejects waste heat to the atmosphere through the cooling of a water stream to a lower temperature. Cooling towers may either use the evaporation of water to remove process heat and cool the working fluid to near the wet-bulb air temperature or, in the case of closed circuit dry cooling towers, rely solely on air to cool the working fluid to near .

Recirculating Coolers | JULABO USA, Inc.

Recirculating Coolers | JULABO USA, Inc.

AWC100 Compact Recirculating Coolers Compact models for applications requiring little cooling performance. JULABO's Air to Water Recirculating Cooler AWC100 is an extremely compact solution, designed to remove small heat loads from external systems such as from Peltier-elements.

Troubleshooting a Marine Fresh Water Cooling System .

Troubleshooting a Marine Fresh Water Cooling System .

Temperature problems . Normal temperatures. Most marine FWC thermostats open at 160°F and will be fully open at approximately 180°F. A new clean system under moderate load should operate at the lower end of this range and a dirty system under full load might operate in the upper range.

Coolant Flow - an overview | ScienceDirect Topics

Coolant Flow - an overview | ScienceDirect Topics

Reducing the coolant circulation rate by reducing pump speed was estimated to represents a reduction in engine parasitic work equivalent to fuel saving about 0.5-1% over the NEDC. The direct effect of reducing coolant circulation rate on temperatures was most evident in the upper parts of the engine, and although there was a clear increase in .

low temperature coolant circulation pump, low temperature .

low temperature coolant circulation pump, low temperature .

offers 196 low temperature coolant circulation pump products. About 44% of these are Pumps, 20% are Laboratory Thermostatic Devices. A wide variety of low temperature coolant circulation pump options are available to you, such as pressure, usage, and application.

6L Low Temperature Cooling Liquid Circulator Pump Chiller .

6L Low Temperature Cooling Liquid Circulator Pump Chiller .

Low Temperature Cooling Liquid Circulator 6L. The refrigeration system has over-heating and over-current multiple protective function. To improve the service life of the refrigeration system, the system adopt startup protection.

Low-temperature coolant circulation pump used with rotary .

Low-temperature coolant circulation pump used with rotary .

The low-temperature coolant circulation pump can directly cool test tubes, reaction flasks, etc. to carry out chemical reactions at low temperatures, and carry out low-temperature storage of chemicals and biological products. It can also be used in conjunction with rotary evaporators, vacuum freeze-drying boxes, circulating water-type multi .

Troubleshooting a Marine Fresh Water Cooling System .

Troubleshooting a Marine Fresh Water Cooling System .

Temperature problems . Normal temperatures. Most marine FWC thermostats open at 160°F and will be fully open at approximately 180°F. A new clean system under moderate load should operate at the lower end of this range and a dirty system under full load might operate in the upper range.

Low-Temp. Cooling Liquid Circulation Pump, Refrigerated .

Low-Temp. Cooling Liquid Circulation Pump, Refrigerated .

-30 to -120°C Split type low temp. chiller, large capacity cooling liquid circulation pump. Model: LLCP Series; Send Inquiry Add To Inquiry List. Description; Middle and large type of ultra low temperature cooling-liquid pump are split design which is convenient for operation and adding the gelatin water.

CHILLERS AND CHILLED WATER SYSTEMS Flashcards | Quizlet

CHILLERS AND CHILLED WATER SYSTEMS Flashcards | Quizlet

On a start sequence the START button is pushed, timer starts, and after a time delay, the oil pump starts and its light illuminates. A ten-second timer starts after oil pressure is greater than 17 psig, after timer times out the low water flow and low oil pressure bypasses are removed, approximately 28 seconds after the oil pump starts, the compressor starts and timer light extinguishes.

Cooling of marine diesel engine - how it works .

Cooling of marine diesel engine - how it works .

The low-temperature circuit circulates the main engine air coolers, the lubricating oil coolers and all other heat exchangers. A regulating valve controls the mixing of water between the high-temperature and low-temperature circuits. A temperature sensor provides a signal The advantages of a central cooling system are;

Ultra-Low Refrigerated-Heating Circulators | JULABO

Ultra-Low Refrigerated-Heating Circulators | JULABO

for working temperatures from -95 °C to +150 °C with filling port upgradeable with additional heating and pump capacity for external control only. Ultra-Low Refrigerated Circulators with SL circulator impress with their high heating, cooling and pump capacities for external temperature control applications.

-80°C 5L Low Temperature Cooling Liquid Circulator Pump .

-80°C 5L Low Temperature Cooling Liquid Circulator Pump .

Molecular Distillation. Chiller /Heater. Cost effective table-top chiller circulator with 5L reservoir and temperature down to -80°C. Advanced internal circulation and external circulation pump system, the internal circulation of low temperature thermostat circulator make the temperature uniformity constant, the external circulation pump output 16 l / min ~ 18 l / min in high flow, low .