Our Products

Rotary Evaporator

Laboratory equipment

Jacketed Reactor

Contact Us

We Cherish All Interactions

Advanced process control improves refinery, chemical plant .

Advanced process control improves refinery, chemical plant .

Aug 07, 2019 · The impurities should be minimized to ensure good selectivity in the reactor. Before , this variable was not under automatic control because the analyzer is a chromatograph with a sample period of 14 minutes, resulting in a long lag time between process variable updates, and consequently poor PID control performance.

Nuclear reactor safety system - Wikipedia

Nuclear reactor safety system - Wikipedia

Reactor protection system (RPS) A reactor protection system is designed to immediately terminate the nuclear reaction. By breaking the nuclear chain reaction, the source of heat is eliminated.Other systems can then be used to remove decay heat from the core. All nuclear plants have some form of reactor protection system.

AutoLAB II | Chemical Reactors from 250 ml to 50 L

AutoLAB II | Chemical Reactors from 250 ml to 50 L

Reactors for Research. H.E.L has supplied stirred jacketed reactor systems to the Chemical R & D community for over 20 years. The AutoLAB range caters for stirred reactors from 250 ml to 50 L or more and is available in a range of configurations to suit any laboratory or application from:

Lab Reactors - Lab Mixers - Lab Stirrers - Homgenizerzs by .

Lab Reactors - Lab Mixers - Lab Stirrers - Homgenizerzs by .

LR-2.ST Lab Reactor: The IKA® LR-2.ST system is a modulary designed miniplant reactor system, planned and designed to simulate and optimize chemical reaction processes as well as mixing, dispersion and homogenization processes at a model scale with a maximum volume of 2000 ml.

High-pressure reactor - Series 2500 Micro Batch System .

High-pressure reactor - Series 2500 Micro Batch System .

The Micro Batch System 2500 is Parr's smallest ever family of stirred reactors, available in a number of configurations. With reactor volumes of 5 mL or 10 mL, independent reactor gas filling, PID temperature control, and a choice of two closure styles, the flexibility of the MBS 2500 is sure to bring value to your small volume, high pressure project.

Artificial Neural Network control of thermoelectrically .

Artificial Neural Network control of thermoelectrically .

The system exhibits several key advantages over thermocouples and PID control including the ability to quantify and account for thermal diffusion in the system, to collect and process data very quickly and with high accuracy, to analyze the entire surface of the reactor, and to update its training based not only on the current thermal response .

Control Engineering | Fundamentals of cascade control

Control Engineering | Fundamentals of cascade control

Aug 17, 2014 · Elements of cascade control . The Cascade Control Block Diagram shows a generic cascade control system with two controllers, two sensors, and one actuator acting on two processes in series. A primary or master controller generates a control effort that serves as the setpoint for a secondary or slave controller.

25000L Titanium Reactor - BORUI

25000L Titanium Reactor - BORUI

25000L Titanium Reactor. Product introduction. NO. Item. Technical Parameters. 1. Nominal volume. 100 L ~ 25000L. 2. . PID Control box. Temperature display and control, control accuracy±1℃; mixing speed display and stepless speed, heating power control and keep automatic constant temperature. . All right reserved (C) Weihai Borui .

Control of a Chemical Reactor

Control of a Chemical Reactor

The PID controller model is included in the standard Modelica library and it is designed according to the model provided in (Astrom and Hagglund 95). It has limited output, anti-windup compensation and setpoint weightings. . Diagram of the reactor Modelica model: a) open-loop system; . View of the chemical reactor virtual-lab. References .

Temperature Control of a Stirred Reactor

Temperature Control of a Stirred Reactor

Using `K_c`, `tau_I`, and `tau_D` from the IMC tuning correlation, implement a PID controller with anti-reset windup. Test the set point tracking capability of this controller by plotting the response of the process to steps in set point of the reactor temperature (not cooling jacket temperature) from 300K up to 320K and then down to 280K.

Modeling a multivariable reactor and on-line model .

Modeling a multivariable reactor and on-line model .

1. ISA Trans. 2005 Oct;44(4):539-59. Modeling a multivariable reactor and on-line model predictive control. Yu DW(1), Yu DL. Author information: (1)Automation Department, Northeast University in Qinhuangdao, China. A nonlinear first principle model is developed for a laboratory-scaled multivariable chemical reactor rig in this paper and the on-line model predictive control (MPC) is implemented .

Simulator of Water Tank Level Control System Using PID .

Simulator of Water Tank Level Control System Using PID .

Control Systems Engineering: Prentice Hall [6] Carl Knopse, Guest Editor, PID Control, IEEE Control System Magazine, February 2006 Control ler Erro r (%) Settling Time (S) Overshoot (%) P-Control ler 4.35 6.23 10.13 PID-Control ler 3.12 4.56 3.76

Parr Instrument Company Stirred Reactors and Pressure Vessels

Parr Instrument Company Stirred Reactors and Pressure Vessels

The Parr Series 5000 Multiple Reactor System . has been designed to provide an integrated . our line of laboratory pressure reactor equip-ment, these reactors are offered with a number . • Temperature monitoring and PID control : of each individual reactor. • Pressure monitoring of each individual :

AutoLAB II | Chemical Reactors from 250 ml to 50 L

AutoLAB II | Chemical Reactors from 250 ml to 50 L

Reactors for Research. H.E.L has supplied stirred jacketed reactor systems to the Chemical R & D community for over 20 years. The AutoLAB range caters for stirred reactors from 250 ml to 50 L or more and is available in a range of configurations to suit any laboratory or application from:

Engineered Systems - De Dietrich Process Systems Chemical .

Engineered Systems - De Dietrich Process Systems Chemical .

De Dietrich Engineered Systems offers of customers the advantage of our knowledge and expertise in reactor and process systems based around one or more of our core technologies: batch processes/reaction, filtration, drying, solids handling, heat transfer, and mass transfer.We will integrate our core equipment with process utilities, instrumentation, automation and controls and other .

Listings in Data acquisition & process control, Reactors .

Listings in Data acquisition & process control, Reactors .

Listings in Data acquisition & process control, Reactors, lined, glass, Tanks, stainless steel, lined and Stainless steels, AISI 400 series

Spare parts and PID control - NEWERA

Spare parts and PID control - NEWERA

Lab testing reactor; Pilot reactor; Industrial reactor; Chemical reactor; Pharmaceutical reactor; Reactor system or production line; Reactor volume; Reactor structure; Reactor material; Reactor pressure and temperature; Mixer; Heat exchanger; Tank and Tower; Spare parts and PID control

Thermal Process Safety Based on Reaction Kinetics and .

Thermal Process Safety Based on Reaction Kinetics and .

The reactor cooling system can be represented by a single heat carrier circulation loop where the temperature controller acts directly on the heating and cooling valves by using a conventional PID .

AUnitOperationsLaboratoryExperimentCombinedwithaComputerSi .

AUnitOperationsLaboratoryExperimentCombinedwithaComputerSi .

temperature and control it at a new set point value of 30 oC. The reactor vessel and associated temperature bath was purchased from Syrris, Ltd as part of a biodiesel reactor system, shown in Figure 2, that we use in a separate lab course1. The number of physical runs that could be made in a four hour lab period was limited because it

High-pressure reactor - Series 2500 Micro Batch System .

High-pressure reactor - Series 2500 Micro Batch System .

The Micro Batch System 2500 is Parr's smallest ever family of stirred reactors, available in a number of configurations. With reactor volumes of 5 mL or 10 mL, independent reactor gas filling, PID temperature control, and a choice of two closure styles, the flexibility of the MBS 2500 is sure to bring value to your small volume, high pressure project.

Series 2500 Micro Batch Reactor System - Parr Instrument .

Series 2500 Micro Batch Reactor System - Parr Instrument .

Features of the Micro Batch System 2500 include: Three reactors with 5 mL or 10 mL volume, available in stainless steel, high-nickel alloys, titanium, zirco­nium, and other exotic materials; Small 10" x 12" (25 cm x 30.5 cm) footprint, with remotely located 4848-based controller for temperature/stirring control and pressure display.

Mass flow controller in reactor vessel application .

Mass flow controller in reactor vessel application .

The reactor pressure is controlled by giving a setpoint to the pressure transmitter. In the illustration this is done via RS232 by a script programmed into a PC. The integrated PID-controller of this pressure meter (Master) controls the valve position of the mass flow controller's control valve (Slave).

Buchiglas - Pressurereactor

Buchiglas - Pressurereactor

Lab reactors are often used as batch reactors. The operation temperature for such reactors can be from –50°C up to +250°C. The basis of our autoclaves or pressure reactors is the design of chemical reactors. Chemical reactors are used for many different processes.

Thermal Control Units (TCU) | Pfaudler

Thermal Control Units (TCU) | Pfaudler

With our reactor, WFE and column technologies at the core, we design complete modular process systems with all ancillary equipment, piping and instrumentation. We lead the way in providing complete process systems as pre-assembled modules, which mean lower project costs, shorter construction schedules and improved quality.

Air & Water Chiller Temperature Control System For Jacket .

Air & Water Chiller Temperature Control System For Jacket .

Dynamic Temperature Control System Advantages And Functions: temperature range from -120 ℃ to 350 ℃, superior performance, high precision, intelligent temperature control. Multi-function alarm system and safety function, 7-inch, 10-inch color TFT touch screen graphic display, magnetic drive pump, no shaft seal leakage problem.

Pressure vessel manufacturer | High pressure reactor

Pressure vessel manufacturer | High pressure reactor

We offer high pressure reactors, vessels and systems upto 700 bar (10000 psi) and 600°C in various materials like SS-316 / 316L, Hastelloy B/C, Monel, Inconel, Nickel, Titanium, Tantalum, Zirconium etc. Our range of equipment varies from lab scale to plant scale for various applications. We offer continuous flow reactor from lab to pilot scale .

Fixed Bed Reactor Unit | Durga Technology Corporation .

Fixed Bed Reactor Unit | Durga Technology Corporation .

Durga Technology Corporation Nashik. Plot No: 23, Survey No. 81-82, Behind 72/73, NMC School, MIDC Ambad, Nashik - 422 010.

PID Loop Tuning Technology - Control Station

PID Loop Tuning Technology - Control Station

What's even more absurd is that those products require users to hold their processes steady before the software can begin to function properly. The irony for most practitioners is that PID tuning software isn't needed if a steady-state can be established – they can tune their loops manually. LOOP-PRO is unlike any other PID tuning software.

Bringing Autonomy to Industrial Control Systems – Microsoft AI

Bringing Autonomy to Industrial Control Systems – Microsoft AI

Autonomous systems use reinforcement learning and machine teaching to bring autonomy to industrial control systems across multiple industries. . Calibrate and Control Polymer Reactors. Reduce the amount of time and product loss when calibrating your polymer reactor. . An operator must tune a PID controller for each piece of equipment .

Thermal Control Units (TCU) | Pfaudler

Thermal Control Units (TCU) | Pfaudler

With our reactor, WFE and column technologies at the core, we design complete modular process systems with all ancillary equipment, piping and instrumentation. We lead the way in providing complete process systems as pre-assembled modules, which mean lower project costs, shorter construction schedules and improved quality.